Zoustech ultrasonic shears for open surgical procedures are offered in two curved-tip configurations: BN-CSD-ZT09 (9 cm shaft) and BN-CSD-ZT17 (17 cm shaft). The scissor-style instrument is presented for soft-tissue cutting, coagulation, grasping and dissection, subject to the manufacturer’s labeled indications and compatible ultrasonic energy system.

Contáctenos

¿Necesita ayuda?
Estamos aquí para atenderle.

Escanee el código para contactarnos por WhatsApp

ISO 13485

Certificación

Calidad

Garantizada

OEM / ODM

Disponible

En todo el mundo

Envíos

Descripción general

Introducción del producto

Designed for open surgical access, these ultrasonic shears feature a curved, tapered distal tip, ring-style controls and two shaft-length options. Supplier product materials describe an ultrasonic cutting and coagulation function and show a torque-wrench-assisted assembly process. The device must be used only with the compatible handpiece/transducer and generator identified in the current manufacturer documentation.

Características principales

Curved, Tapered Tip

Distal jaw geometry designed for positioning and manipulation of tissue in an open surgical field.

Cutting and Coagulation

Supplier materials describe tissue cutting and coagulation using ultrasonic energy. Performance and indications must be confirmed against the current IFU.

Ergonomic Ring Handles

Scissor-style ring controls provide a familiar hand positioning format and jaw actuation.

Two Shaft-Length Options

9 cm and 17 cm shaft versions are identified in the supplied model chart.

Multi-Function Jaw Assembly

Supplier materials describe cutting, coagulation, grasping and dissection functions. Use only within the labeled indications.

Ultrasonic Energy Mechanism

Ultrasonic instruments use mechanical vibration at the active blade; thermal effects and surgical plume can still occur during activation.

Componentes del producto

Curved Tip and Jaw Assembly

The instrument features a curved distal tip and opposing jaw designed for tissue grasping and manipulation during open surgical procedures.

Instrument Shaft

Available in two shaft lengths, 9 cm and 17 cm, to accommodate different open surgical access requirements.

Ergonomic Ring Handles

The scissor-style ring handles provide a familiar hand positioning design for instrument manipulation and jaw control.

Adjustment Controls

The instrument features adjustment controls positioned near the handle for convenient access during operation.

Especificaciones técnicas

Product Code
Shaft Length
Surgical Approach
Tip Configuration
BN-CSD-ZT09 9 cm Open Curved
BN-CSD-ZT17 17 cm Open Curved

Uso previsto

These instruments are presented for open surgical soft-tissue procedures involving dissection, cutting and coagulation. Exact anatomical applications, indications, contraindications and use limitations must be taken from the current manufacturer IFU and applicable market authorization. No specialty-specific claim is made here without that evidence.

Preguntas frecuentes

Encuentre respuestas a preguntas frecuentes sobre las características, aplicaciones, especificaciones y servicios OEM de nuestros productos.

| Are these ultrasonic shears for open or laparoscopic surgery?

The supplied model chart identifies both BN-CSD-ZT09 and BN-CSD-ZT17 for open surgery.

| What shaft lengths are available?

Two options are listed: 9 cm (BN-CSD-ZT09) and 17 cm (BN-CSD-ZT17).

| What is the distal tip design?

The supplier imagery shows a curved, tapered tip.

| What functions does the device support?

Supplier materials describe cutting, coagulation, grasping and dissection; consult the current IFU for labeled functions.

| Which generator is compatible?

Compatibility is not established by the supplied images. Request the manufacturer’s model-specific compatibility list.

| Which handpiece or transducer is required?

The exact compatible handpiece/transducer must be confirmed using the manufacturer’s documentation.

| Is the product supplied sterile and is it single-use?

The supplied images do not establish sterility or reuse status. Confirm the final label and IFU.

| Is a torque wrench included?

A wrench appears in the supplier packaging and assembly materials; confirm the contents of each ordered SKU.

| What regulatory documents are available?

Request current declarations, certificates and applicable product registration documents for the destination market. CE status has not yet been confirmed.

| Are OEM or samples available?

The supplier listing indicates OEM/private-label and sample availability; confirm commercial terms and regulatory labeling responsibilities before ordering.

 

Why Choose Zoustech

Zoustech presents two identifiable open-surgery configurations with curved distal jaws, ring-style handling and supporting product imagery. Our team can assist professional buyers with model selection inquiries and requests for technical documentation. Final compatibility, labeling, regulatory and supply details must be confirmed for each order.

Request Product Information

For model specifications, compatibility documentation, sample inquiries or distributor discussions, contact Zoustech.

Website: www.hzzoustech.com
Email: zoustech02@gmail.com

Scroll al inicio